JIAXING JINGYANG CONSTRUCTION MACHINERY CO.,LTD profile
Jiaxing Jinngyang Construction Machinery Co.,Ltd is a professional factory in construction machinery, equipment, material & spare parts. Dedicated to provide a complete solution to mechanical & civil construction with quality products and perfect service Enjoying good reputation of business by respecting & satisfying our customers. Looking back to the past, we have made one brilliant achievement after another with our efforts and your support. Looking forward to the future, we are determined to be with you as always on the way to greater success and win-win results.We have following Tower crane, passenger hoist, suspended platform,electric winch, electric hoist, gear rackand pinion, worm and shaft, electric units, scaffolding and etc. In addition to the good quality of our products,we also have our profrssional technical service provide the clients with our best after-service. We have supplied more than 80 units of passenger hoist, 140 units of suspended cradle to the market since 2007. |
Passenger hoist mckke calling phone
INTRODUCTION
The system is used in the industrial elevator of the building elevator and the construction hoist.
This system provides an emergency call between the construction of the floor inside the building and elevator driver, can be used as a general intercom system.Because the radio frequency does not need to apply, the product can be used in the construction of the elevator intensive areas of reliable use, will not affect each of the reliable communication. It greatly improves the product efficiencyand can effiectively prevents acidents.
FUNCTIONAL CHARACTERISTICS
1:The signal transmission is carried out by using the protection loop line, the signal is stable and reliable, and the special communication cable is not required.
2:The signal line and power line a re not connected with high voltage, and the system is safe and reliable.
3:No elect romagnetic wave pollution, don’ t need to apply for radio frequency can be used in the construction of the elevator intensive and authentic and other construction a reas, and will not affect each other.
4:Press the button for intercome function, it can prompt the communications is bus also has the squelch function.
5:Elec ronic volume control, convenient volume adjustment.
6:There is alarm button, can be used in emergency condition.
7:Three frequencies available, voice clear and naturral.
SPECIFICATION PARAMETER
1:Supply voltage 220VAC or 110VAC (Please make sure that when the order confirmed!)
2:Effective range more than 300 meter (Conductor loop resistance<600 ohm)
3:Three frequencies available 250KHz 741KHz or 800KHz
SYSTEM INSTALLATION
The installation method of the intercome on each floor can be referenced to the left of the following view. Fit the intercom and connect the intercom with the accessory cable. Note: a dedicated power supply device can only drive less than twenty. In another with the drawings, another port dedicated power supply connected to the junctionand then connected to the coupler. In the first floor of the construction elevator, the protective ground wire passes through the hole of the coupler, and it’s connect to the ground. Important note for installation, in the communication system, the protect grounding wire passing through the coupler can not be grounded in the middle grade.
The installation method of the cage intercom see below right view. Inaccording with the drawings, connect the intercom, the call device power supply, and the coupler cage, the protective ground wire passes through the hole of the coupler, and it connected with the ground.
Note: The power supply of the calling device and the special power output
have the difference between 110V AC and 220V AC. Please make sure that w
hen the order is confirmed! |
Technical date
Date show
|
wind speed and wind power shown
|
Power
|
DC 12V±1%
|
Insulation ability
|
≥10MΩ
|
Dimensions
|
190mm×106mm×53mm
|
Power dissipation
|
≤15W
|
Alarm wind power settings
|
Depend on your requirement
|
Description of terminal of special power supply device:
NO |
CABLE |
EXPLAIN |
1 |
L |
Power(Blue) |
Three core cable |
2 |
N |
Power(Brown) |
|
3 |
G |
Ground(Yellow) |
|
4 |
-V |
Cable shield |
The four core shielded cable |
5 |
-V |
Negative power(Brown) |
|
6 |
+V |
Positive power(Black) |
|
7 |
+V |
Positive power(Blue) |
|
SYSTEM INSTRUCTIONS
INTERCOME UNIT
After the power supply is turned on, the channel frequency LED and the Transmitting receiving LED are red at the same time. At this time, if the system is not used, they turn green. If possible use the intercome, the channel frequency LED is red. At this time, push buttons to adjust volume, Press”talk” button and talk to the microphone above emergency while the channel frequeny indicator’s green.(effective range 10-20cm.)
Change Channel
1:Press and hold the switch.
2:Press and hold the “EMERGENCY ALARM” switch. The alarm will no
t sound. Do not release this switch until the channel is set.
3:Press on and off the button 4 times, until the “CHANNEL” LED color
changes. This switch must be pressed three times to activate the chann
el change mode. Then the CHANNEL LED Color (channel) will change
with each press of the switch.
4:When the Channel LED is the color desired, release the “EMERGENCY
ALARM” switch. The channel is now set.
State |
Explain |
Green LED |
Channel 1, 250KHz (FactoryDefault) |
Red LED |
Channel 2, 741KHz |
Green + Red LED |
Channel 3, 800KHz |
Description of three operation frequency States
IMPORTANT: Each unit in a system must be set to the same channel(LED color) to communicate. The channel setting is shown is shown by the color of the”CHANNEL” tricolor LED when the unit is powered up.
Power Unit
When the AC power supply is suddenly interrupted, the whole system is powered by the BD-110VAC (or BD-220VAC) backup power supply, which is automatically closed after1 hours of continous power supply. If the system needs to work,press the red reset switch on it’s shell to restart the battery power supply. BD-110VAC (or BD-220VAC) battery backup power supply, such as the need to tun off the power supply, please press the reset switch.
When the AC power supply is provided, the system automatically switches to the normal power supply state, and the battery in the backup power supply of BD-110V BD-220VAC) is charged.Backup power output 12VDC, 0.5Amp.
State |
Explain |
Green and red LED on |
110VAC or 220VAC input, 12V output. |
Green LED on |
220VAC malfunctioning, backup power unit kick in. |
Green and Red LED blinking |
system overload, both green and red LED return to normal
after reboot. |
Green LED bliking |
Too low voltage. |
|
RFQ
Are you trading company or manufacturer ?
A: We are factory.
Q: How long is your delivery time?
A: Generally it is 3-7 days if the goods are in stock. or it is 15-20 days if the goods are not in
stock, it is according to quantity.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
Q: What is your terms of payment ?
A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance
before shippment.
If you have another question, pls feel free to contact us as below:
Item |
Part No. |
English name |
Item |
Part No. |
English name |
1 |
DL-0 |
Cage |
31 |
WG-19 |
Worm gear fan |
2 |
WG-0 |
Reducing device |
32 |
MAC-8 |
Rubber |
3 |
MAC-010 |
Motor |
33 |
WG-5 |
Woem wheel |
4 |
ZJ-0 |
Mast section |
34 |
WG-15 |
Worm |
5 |
XS-00 |
Safety device |
35 |
MAC-9 |
Couping |
6 |
HY |
Hydraulic spring |
36 |
MAC-020 |
Pinion |
7 |
TIE |
Tie-in |
37 |
ZJ100-10 |
Rack |
8 |
TL-2 |
Safety device spanner |
38 |
XK |
Drop test operate box |
9 |
PJ |
Pipe joint |
39 |
CT |
Out operate box |
10 |
BL100-G |
Roller |
40 |
FR |
Resistance |
11 |
BH-10 |
Cable joint |
41 |
PS |
Waterproof plug |
12 |
ML100-9 |
Gate roller lower |
42 |
SE |
3-phase swotch |
13 |
ML100-10 |
Gate roller upper |
43 |
TC |
Transfprmer |
14 |
WM130-40 |
Rope pulley |
44 |
SDD |
Annunciator |
15 |
BS-10 |
“J ” type screw |
45 |
PLC |
PLC Module |
16 |
BQ-10 |
Cable joint |
46 |
QF |
Creepage switch |
17 |
BM-24 |
Screw |
47 |
SL |
Limit switch |
18 |
TL-1 |
Roller spanner |
48 |
FM |
Belling |
19 |
RA-9 |
Adjustment unit |
49 |
JS |
Jacket |
20 |
RA-12 |
Brake pad |
50 |
FS |
Fan |
21 |
SP |
Spring |
51 |
SY |
EL lock |
22 |
DL-110 |
Rubber pad |
52 |
F |
Drop test plug |
23 |
WG-03 |
Brearing |
53 |
KCE |
Thermal relay |
24 |
WG-030 |
Oil seal |
54 |
SQ |
Braker |
25 |
DXI-5 |
Nylon wheel |
55 |
KMB |
Contactor |
26 |
RA-13 |
Rotary disk |
56 |
BR |
Brake unit |
27 |
RA-120 |
Brake piece |
57 |
SPL |
Speed relay |
28 |
RA-10 |
Brake disc |
58 |
EL |
Lamp |
29 |
RA-7 |
Electromagnet |
59 |
CS |
Calling system |
30 |
CAM-3 |
Counter roller |
60 |
OL |
Overload |
|
Contact us
Skype:mickey1987888
Tel: +86 0573-84187637
Fax:+86 0573-841876376
Whatsapp& Mobile:+0086 18267343860Add: No.1111,xiehe park, nanhu district, jiaxing of Zhejiang province, China. Close to Shanghai (Post code: 314000)
Email:mickey@jingyangmachinery.com
Web:www.jingyanghoist.com / www.jingyangmachinery.com / www.jingyangroup.com
Jiaxing Jingyang Construction Machinery Co.,Ltd. |